PETAlyze
No study loadedUse Open DICOM or Folder, or drop DICOM files, folders or ZIP archives here.
PET MIP
Drop DICOM files, folders or ZIP archives
Reading…

Series found

Controls

Mouse

  • Wheel: always scrolls the slices (on the MIP it rotates the projection)
  • Navigate mode (scrolling): left-drag scrolls the slices, click sets the cursor, right-drag zooms
  • Magnifier mode (pan/zoom): left-drag pans the image, right-drag zooms
  • Zoom is always centred on the view, wherever the mouse is
  • In the other tools: right-drag zooms, Shift + left pans
  • Middle-drag or Alt + left: CT window (in the PET view: SUV scale)
  • Ctrl + wheel / trackpad pinch: zoom · + − ⤢ buttons on each view · double-click enlarges the view

Suggested workflow

  1. Check weight, dose and times: the SUV updates at once.
  2. Place the Liver reference (and the blood Pool).
  3. Segment all uptakes with the chosen threshold (e.g. SUV 4.0 or PERCIST).
  4. Confirm every uptake with A (pathological) or X (physiological); Delete removes a contour, the Eraser separates merged contours.
  5. Add the missing findings with Finding: click on the lesion or drag a sphere around it.
  6. Enter the location: total MTV and TLG update in real time.

Keyboard

  • N Z W R V S D E M F B: tools
  • + / −: zoom of the active view · 0: fit · H: maximum image area
  • 1 2 3: CT, PET, Fusion
  • ↑ ↓ / PgUp PgDn: slice in the active view
  • Ctrl+Z: undo · Del: delete the selected finding · Home: reset view
  • A / Q / X: classify the selected uptake as pathological / equivocal / physiological · ← →: previous / next uptake
  • C: show/hide the contours · T: scissors (draw an area around the part to separate)

Uptake confirmation

  1. Method (Segmentation panel), a single one for detection and contour. SUV ≥ 4.0, SUV ≥ 2.5 and PERCIST are absolute thresholds: each finding is a connected region with all voxels above the threshold and a volume of at least the minimum volume; nothing below the threshold is included.
  2. 41% SUVmax, A50P, MV2, MV3 contour each lesion from its own maximum: the uptakes are found as regions with SUV ≥ 2.5 (≥ minimum volume). If the contour of the method spills into the background, the finding is limited to its uptake (SUV ≥ 2.5) and flagged “contour limited”. Extended MTV: SUV ≥ 4.0 for the uptakes above 4, A50P for those below the threshold.
  3. SUV ≥ 4.0 · ≥ 3 ml preset (PETRA workflow in 4 steps): ① automatic preselection of the SUV ≥ 4.0 regions of at least 3 ml; ② X on the physiological uptakes; ③ click with the Finding tool on the missed lesions (< 3 ml); ④ review and confirm with A. SUV ≥ 4.0 · from 0 ml preset: all SUV ≥ 4.0 regions, of any volume. SUV ≥ 2.5 preset: all regions with SUV ≥ 2.5 of at least 0.5 ml. With PERCIST the liver, if missing, is estimated from the CT.
  4. With Exclude the brain on, the large cranial uptake is marked physiological (green); no other organ is excluded automatically.
  5. All other uptakes, including those added by hand, are to confirm (orange): A = pathological (red), Q = equivocal (purple), X = physiological (green); ← → step through the uptakes.
  6. The site of each uptake is proposed from the CT (lung/lobe, bone/vertebra, lymph node stations, liver, spleen…): it is marked “automatic site” until you edit it.
  7. MTV, TLG and the MTV report count only the pathological lesions; equivocal ones are excluded from the totals and listed separately, those still to confirm are excluded.
  8. Deauville (References panel → Deauville): with liver and mediastinal blood pool placed, it computes the 5-PS score of each lesion and flags the target lesion, the most avid of the pathological ones (provisionally among all non-physiological ones until you confirm one). Lugano reading (SUVmax vs blood pool and liver, 5 from 2–3× liver SUVmax) or qPET (SUVpeak / liver SUVmean: 0.95 · 1.3 · 2.0). Score and target appear in the list, on the images, on the MIP and in the report.
  9. Review (top bar): axial CT, PET and Fusion without side panels, with the confirmation bar; in the bar choose the Horizontal or Vertical layout.
  10. Scissors: draw a closed area around the part of the uptake to separate (for example physiological activity touching a lesion). That part becomes a finding of its own, to be classified; the rest keeps its number and classification. The area extends over all slices (only where the uptake continues), over the displayed slice only, or from here upwards / downwards: useful when the two uptakes touch one above the other.

Lungs (experimental)

  • Segment lungs, lobes and segments: lung mask from the CT, lobes and 18 segments estimated with a model of the fissures
  • Overlay by lobes or segments with labels; the status bar shows the lobe and segment under the cursor
  • Assign the lung site fills in the location of the intrapulmonary findings (estimate to be checked)

Segmentation methods

  • SUV ≥ 4.0 and SUV ≥ 2.5: fixed thresholds; with SUV ≥ 4.0, preselection of the regions ≥ 3 ml (PETRA)
  • 41% of SUVmax: isocontour of each lesion
  • PERCIST: 1.5 × liver SUVmean + 2 SD
  • A50P: background + 50% × (SUVpeak − background), background = median of the shell around the lesion
  • MV2 / MV3: voxels included by at least 2 / 3 of the methods SUV 2.5 · SUV 4.0 · 41% · A50P
  • Extended MTV: SUV ≥ 4.0, plus A50P for the lesions with SUVmax < 4
PETAlyzeResearch use only

Please read before use.

Your data stay on your computer

Intended use and limitations

syngo.via is a trademark of Siemens Healthineers AG. Fonts: IBM Plex, SIL Open Font License 1.1.